Power range: 5.5~400KW (low voltage)
Frame range: H112~H400
Service factor: 1.1, 1.5, 1.2
Frame material: gray cast iron or steel plate welding
Mounting: B3, B35, B5, V1
Protection: IP54 IP44 IP23
Cooling: IC411 IC416
PTC, PT100 and other thermal elements can be chose to protect winding and bearings.
Various voltages and frequencies can be chose.
Cable length can be chose.
环境 适台IP55防护等级的安装 低于或等于海拔i1000米 环境温度在-15℃-40℃ 相对湿度 |
Operating Environment Suitable for IP55 installations Altitude not exceed 1000m Ambient temperature -15℃ - 40℃ Relative humidity |
温度 Temperature | 相对湿度 Relative Humidity |
-15℃ ≤ T ≤ 20℃ | 100% |
20℃ ≤ T ≤ 30℃ | 95% |
30℃ ≤ T ≤ 40℃ | 55% |
<30℃ | 30℃~40℃ | 45℃ | 50℃ | 55℃ | 60℃ | |
1000m | 1.07 | 1.00 | 0.96 | 0.92 | 0.87 | 0.82 |
1500m | 1.04 | 0.97 | 0.93 | 0.89 | 0.84 | 0.79 |
2000m | 1.00 | 0.94 | 0.90 | 0.86 | 0.82 | 0.77 |
2500m | 0.96 | 0.90 | 0.86 | 0.83 | 0.78 | 0.74 |
3000m | 0.92 | 0.86 | 0.82 | 0.79 | 0.75 | 0.70 |
3500m | 0.88 | 0.82 | 0.79 | 0.75 | 0.71 | 0.67 |
4000m | 0.82 | 0.77 | 0.74 | 0.71 | 0.67 | 0.63 |